GCMS MPS DualHeadSPEmVAP

gerstel

Automated SPE Option for standard cartridges, improved recovery, precision and reproducibility. Maximized sample throughput by performing SPE during GC or LC analysis of the preceding sample.

Web Product page

Automated Solid Phase Extraction SPE

Performing Solid Phase Extraction (SPE) manually can be time consuming and nerve-racking, especially when recovery and reproducibility are lacking due to sample variability. If Solid Phase Extraction (SPE) can be reliably automated, it becomes a much more efficient and reproducible process.

The GERSTEL Multi Purpose Sampler (MPS) with Automated SPE Option for standard cartridges provides several benefits compared with manual Solid Phase Extraction:

 

  • Improved recovery, precision and reproducibility
  • Maximized sample throughput by performing SPE during GC or LC analysis of the preceding sample
  • More than 50 percent time saving for overall analysis, compared to manual processing

Following the SPE clean-up steps, the MPS can introduce the sample extract directly to an LC/MS or GC/MS system for analysis. As an alternative, the MPS WorkStation is used as a stand-alone sample preparation robot, preparing samples for multiple LC/MS or GC/MS systems in your laboratory.
The GERSTEL SPE enables automated sample preparation and analysis even for complex samples. Samples are prepared in a simple and safe manner combining accurate results with high throughput.

Features:

Easy transfer of your established manual methods
The GERSTEL SPE is based on standard 1 mL, 3 mL, and 6 mL SPE cartridges fitted with transport adapters. Standard cartridges pre-mounted with transport adapters are readily available from several leading suppliers. Manual SPE methods can be directly transferred to the MPS and automated.

High throughput
Analysis of up to 98 samples including sample preparation using standard SPE cartridges.

Efficient
All sample preparation steps are performed during GC/MS or LC/MS analysis of the preceding sample for highest productivity and system utilization.

Optimized timing for each and every sample
All samples receive identical treatment for best reproducibility. Sample introduction to the GC/MS or LC/MS system follows immediately after sample preparation.

Highly controlled analysis conditions
Defined volumes and constant flow rates provide highly reproducible conditions and optimal results independent of variations in sample matrix.

Internal Standard Addition
Automated liquid standard addition provides improved Quality Assurance.

Contamination free
Transfer of eluent from the SPE cartridge to the sealed sample vial is performed using a disposable syringe needle, eliminating the risk of carry over.

Simple concept, highly rugged and efficient
Conditioning, extraction and elution of the cartridge is performed in one dedicated module with minimal movement of the cartridge ensuring highest efficiency and ruggedness.