Gas Chromatograph instrument Agilent 7890B - SRA Instruments

GC7890


Technology:GC

Agilent Technologies

Advanced Gas Chromatograph instrument with carrier gas options that reduce helium levels

Description

When operating budgets are a concern, the 7890B Gas Chromatography System offers innovations that demonstrate real value. The 7890B GC delivers performance not possible in previous GC systems; performance and modularity of GC and MS detection systems provide increased sensitivity. Additional innovations include: precise carrier and detector gas control, early maintenance feedback, and out-of-the-box application Analyzers.

Features

  • Retention Time Locking (RTL) maintains exact retention times from injection to injection, column to column, instrument to instrument, and lab to lab
  • Capillary Flow Technology (CFT) provides unique instrument capabilities, such as multi-dimension gas chromatography (GC-GC/Deans Switch), comprehensive two-dimension gas chromatography (GCxGC) with flow modulation, and backflush at the beginning, middle, or end of the analytical column
  • Single filament TCD that does not require a separate reference gas, does not require manual potentiometer adjustment, and provides a stable baseline with a minimal amount of signal drift
  • Auto-ranging FID provides the ability to detect and quantitate from parts per billion (ppb) to parts per thousand in a single injection
  • Integrated SCD/NCD (sulfur or nitrogen chemiluminescence detector) provides low ppb detection, equi-molar response, and quantitation for sulfur or nitrogen contaminants without quenching from matrix
  • Carrier Gas Options: Helium Conservation Module, Hydrogen Sensors and Alternate Carrier Gas Solutions dramatically reduce the amount of helium used to offer flexibility in your laboratory
  • Large Valve Oven (LVO) allows for the combination of multiple methods and simplified maintenance
  • Multimode inlet (MMI) serves as a programmable temperature vaporizing injector with flexible capabilities
  • Agilent Inert Flow Path provides increased sensitivity for active compounds, from injection to detection
  • Low Thermal Mass (LTM) modules, up to 4 installed and operating, increase sample throughput with rapid column heating and cooling
Related products

Request information

Fill out the form to be contacted by the line manager Armando Miliazza

What's the reason for your visit?
I'm interested in distributing your productsCan the sales department contact me?To request technical assistance service

Privacy Policy
Marketing activities:
I consentI do not consent
Profiling:
I consentI do not consent